9300 vector frequency inverter 15 ... 30 kW EVF9327-EV, EVF9328-EV, EVF9329-EV

9300 vector frequency inverter 15 ... 30 kW EVF9327-EV, EVF9328-EV, EVF9329-EV


Installing the basic device

Basic devices in the power range 0.37 ... 11 kW Mounting with fixing rails (standard)

 

4

4.1 4.1.1


 

4.1             Basic devices in the power range 0.37 ... 11 kW

 

4.1.1         Mounting with fixing rails (standard)

Required mounting material from the scope of supply:

 

Description

Use

EVF9321    

EVF9324

EVF9325,

EVF9326

Amount

Fixing rails

Drive controller fixing

2

4

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9300vec114

Fig. 4.1-1       Standard mounting with fixing rails 0.37 ... 11 kW

囚    Drive controllers can be mounted side by side without spacing

 

9300 vector

Type

Dimensions [mm]

a

b

b1

c

c1

d

d1

e 1)

g

k

EVF9321-EV

EVF9322-EV

囚

78

384

350

39

-

365

–

250

6.5

30

EVF9323-EV

EVF9324-EV

囚

97

384

350

48.5

-

365

–

250

6.5

30

EVF9325-EV

EVF9326-EV

回

135

384

350

21.5

92

365

–

250

6.5

30

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables Mounting                                     ƒ Attach the fixing rails to the housing of the drive controller.

 

 

 

 

 

 

 

 

 

 

 


EDSVF9333V  EN  3.0-06/2005

                                 4.1-1


 


4

4.1 4.1.2

 

Installing the basic device

Basic devices in the power range 0.37 ... 11 kW

Thermally separated mounting (push-through technique)


 

4.1.2         Thermally separated mounting (push-through technique)

For  mounting  in  push-through  technique, the  drive  controller  of type EVF93xx-EV must be used. In addition, the mounting set for push-through technique is required.

 

Type

Mounting set

Type

Mounting set

EVF9321-EV,

EVF9322-EV

EJ0036



EVF9323-EV,

EVF9324-EV

EJ0037

EVF9325-EV,

EVF9326-EV

EJ0038

 


Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting cutout in control cabinet

Fig. 4.1-2       Dimensions for thermally separated mounting 0.37 ... 11 kW

 

9300 vector

Type

Dimensions [mm]

a

a1

b

b1

C

c1

d

d1

e 1)

f

g

EVF9321-EV

EVF9322-EV

圓

112.5

78

385.5

350

60

95.5

365.5

105.5

250

92

6.5

EVF9323-EV

EVF9324-EV

圓

131.5

97

385.5

350

79

114.5

365.5

105.5

250

92

6.5

EVF9325-EV

EVF9326-EV

回

169.5

135

385.5

350

117

152.5

365.5

105.5

250

92

6.5

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

 

9300 vector

Type

Dimensions [mm]

Width

Height

EVF9321-EV

EVF9322-EV

圓

82

350

EVF9323-EV

EVF9324-EV

圓

101

350

EVF9325-EV

EVF9326-EV

回

139

350

 


 

 

 

 

 

 


4.1-2                                                                      

EDSVF9333V  EN  3.0-06/2005


 


Installing the basic device

Basic devices in the power range 0.37 ... 11 kW Mounting in ”cold plate” technique

 

4

4.1 4.1.3


 

4.1.3         Mounting in ”cold plate” technique

 

The drive controllers can be mounted in ”cold plate” technology, e.g. on collective coolers. For this purpose, the drive controllers oftype EVF93xx-CV must be used.

Required mounting material from the scope of supply:

 

Description

Use

EVF9321

EVF9322

EVF9323

EVF9324

EVF9325

EVF9326

Amount

Fixing bracket

Drive controller fixing

2

2

2

Sheet metal screw

3.5 × 13 mm (DIN 7981)

Mounting of fixing bracket to the drive controller

6

6

6

 


Requirements for collective coolers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient conditions

The following points are important for the safe operation of drive controllers:

ƒ Good thermal connection to the cooler

– The contact surface between collective cooler and drive controller must be at least as large as the cooling plate of the drive controller.

– Flat contact surface, max. deviation 0.05 mm.

– Connect the collective cooler with all specified screw connections with the drive controller.

ƒ Adhere to thermal resistance Rth given in the table. The values apply to the operation of drive controllers under rated conditions.

 

9300 vector

Type

Cooling path

Drive controller earth

Power to be dissipated Pv [W]

Heat sink - surroundings Rth[K/W]

[kg]

EVF9321-CVV003

24

1.45

3.9

EVF9322-CVV003

42

0.85

3.9

EVF9323-CVV003

61

0.57

4.5

EVF9324-CVV003

105

0.33

4.7

EVF9325-CVV003

180

0.19

6.1

EVF9326-CVV003

360

0.10

6.1

ƒ The rated data and the derating factors at increased temperature also apply to the ambient temperature of the drive controllers.

ƒ Temperature at the cooling plate of the drive controller: max. 75 °C.


 


4

4.1 4.1.3

 

Installing the basic device

Basic devices in the power range 0.37 ... 11 kW Mounting in ”cold plate” technique


 

 


Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting

Fig. 4.1-3       Dimensions for mounting in ”cold plate” technique 0.37 ... 11 kW

 

9300 vector

Type

Dimensions [mm]

a

b

b1

c

c1

d

e 1)

g

EVF9321-CVV003

EVF9322-CVV003

囚

78

381

350

48

–

367

168

6.5

EVF9323-CVV003

EVF9324-CVV003

圓

97

381

350

67

–

367

168

6.5

EVF9325-CVV003

EVF9326-CVV003

回

135

381

350

105

38

367

168

6.5

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Apply  heat conducting  paste  before  screwing together the  cooler and cooling plate of the drive controller so that the heat transfer resistance is as low as possible.

1.  Fasten the fixing bracket with sheet metal screws 3.5 × 13 mm at the top and bottom of the drive controller 回.

2.  Clean the contact surface of cooler and cooling plate with spirit.

3. Apply a thin coat of heat conducting paste with a filling knife or brush.

– The heat conducting paste in the accessory kit is sufficient for an area of approx. 1000 cm2.

4.  Mount the drive controller on the cooler.


 


Installing the basic device

Basic devices in the power range 15 ... 30 kW Important notes

 

4

4.2 4.2.1


 

4.2             Basic devices in the power range 15 ... 30 kW

 

4.2.1         Important notes

The accessory kit is located in the inside of the drive controller.

Remove the cover of the drive controller                                                                                       

 

4.2.2         Mounting with fixing brackets (standard)

Mounting material required from the scope of supply:

 

Description

Use

Amount

Fixing bracket

Drive controller fixing

4

Raised countersunk head screw M5 × 10 mm (DIN 966)

Mounting of fixing bracket to the drive controller

4

 


 


4

4.2 4.2.2

 

Installing the basic device

Basic devices in the power range 15 ... 30 kW Mounting with fixing brackets (standard)


 

 

Dimensions

 

9300vec111

Fig. 4.2-1       Standard mounting with fixing brackets 15 ... 30 kW

囚    Drive controllers can be mounted side by side without spacing

 


9300 vector

Type

   b1


EVF9327-EV

EVF9328-EV

EVF9329-EV

250

402

350

22

206

370

24

250

6.5

24

11

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting                                     ƒ Attach the fixing bracket to the heatsink plate of the drive controller.


 


Installing the basic device

Basic devices in the power range 15 ... 30 kW Thermally separated mounting (push-through technique)

 

4

4.2 4.2.3


 

4.2.3         Thermally separated mounting (push-through technique)

 


 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting cutout in control cabinet

For  mounting  in  push-through  technique, the  drive  controller  of type EVF93xx-EV  must  be  used.  In  addition,  the  mounting  set  for  EJ0011 push-through technique is required.

 

9300vec116

Fig. 4.2-2       Dimensions for thermally separated mounting 15 ... 30 kW

9300 vector

Type

Dimensions [mm]

a

a1

b

b1

c1

c2

c3

d

d1

d2

d3

e 1)

e1

g

h

EVF9327-EV

EVF9328-EV

EVF9329-EV

279.5

250

379.5

350

19

131

243

361.5

32

100

97

250

159.5

6

9

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

9300 vector

Type

Dimensions [mm]

Width

Height

EVF9327-EV

EVF9328-EV

EVF9329-EV

236

336

 


 


4

4.2 4.2.4

 

Installing the basic device

Basic devices in the power range 15 ... 30 kW Mounting in ”cold plate” technique


 

4.2.4         Mounting in ”cold plate” technique

 


 

 

 

 

 

 

 

 

 

 

Requirements for collective coolers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient conditions

The drive controllers can be mounted in ”cold plate” technology, e.g. on collective coolers. For this purpose, the drive controllers oftype EVF93xx-CV must be used.

The following points are important for the safe operation of drive controllers:

ƒ Good thermal connection to the cooler

– The contact surface between collective cooler and drive controller must be at least as large as the cooling plate of the drive controller.

– Flat contact surface, max. deviation 0.05 mm.

– Connect the collective cooler with all specified screw connections with the drive controller.

ƒ Adhere to thermal resistance Rth given in the table. The values apply to the operation of drive controllers under rated conditions.

 

9300 vector

Type

Cooling path

Drive controller earth

Power to be dissipated Pv [W]

Heat sink - surroundings Rth[K/W]

[kg]

EVF9327-CVV003

410

0.085

13

EVF9328-CVV003

610

0.057

13

ƒ The rated data and the derating factors at increased temperature also apply to the ambient temperature of the drive controllers.

ƒ Temperature at the cooling plate of the drive controller: max. 75 °C.


 


Installing the basic device

Basic devices in the power range 15 ... 30 kW Mounting in ”cold plate” technique

 

4

4.2 4.2.4


 

 


Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting

Fig. 4.2-3       Dimensions for mounting in ”cold plate” technique 15 ... 22 kW

 

 

EVF9327-CVV003

EVF9328-CVV003

234

250

381

350

110

220

367

171

6.5

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Apply  heat conducting  paste  before  screwing together the  cooler and cooling plate of the drive controller so that the heat transfer resistance is as low as possible.

1.  Clean the contact surface of cooler and cooling plate with spirit.

2. Apply a thin coat of heat conducting paste with a filling knife or brush.

– The heat conducting paste in the accessory kit is sufficient for an area of approx. 1000 cm2.

3.  Mount the drive controller on the cooler.


 


 


Installing the basic device

Basic devices in the power range 45 ... 55 kW Important notes

 

4

4.3 4.3.1


 

4.3             Basic devices in the power range 45 ... 55 kW

 

4.3.1         Important notes

The accessory kit is located in the inside of the drive controller.

Remove the cover of the drive controller                                                                                       

 

4.3.2         Mounting with fixing brackets (standard)

Mounting material required from the scope of supply:

 

Description

Fixing bracket

Use

Drive controller fixing

Amount

4

Hexagon head cap screw M8 × 16 mm (DIN 933)

Mounting of fixing bracket to the drive controller

4

Washer g 8.4 mm (DIN 125)

For hexagon head cap screw

4

Spring washer g 8 mm (DIN 127)

For hexagon head cap screw

4

 


 


4

4.3 4.3.2

 

Installing the basic device

Basic devices in the power range 45 ... 55 kW Mounting with fixing brackets (standard)


 

Dimensions

 

Fig. 4.3-1       Standard mounting with fixing brackets 45 ... 55 kW

囚    Drive controllers can be mounted side by side without spacing

 

9300 vector

Type

Dimensions [mm]

a

b

b1

c

c1

d

d1

e 1)

g

k

m

EVF9330-EV

340

580

510

28.5

283

532

38

285

11

28

18

EVF9331-EV

340

672

591

28.5

283

615

38

285

11

28

18

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting                                     ƒ Attach the fixing bracket to the heatsink plate of the drive controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


4.3-2                                                                      

EDSVF9333V  EN  3.0-06/2005


 


Installing the basic device

Basic devices in the power range 45 ... 55 kW Thermally separated mounting (push-through technique)

 

4

4.3 4.3.3


 

4.3.3         Thermally separated mounting (push-through technique)

For  mounting  in  push-through  technique, the  drive  controller  of type EVF93xx-EV  must  be  used.  In  addition,  the  mounting  set  for  EJ0010 push-through technique is required.

 

 

Fig. 4.3-2       Dimensions for thermally separated mounting 45 ... 55 kW

  a    a1     b     b1   c1    c2       c3      c4     d    d1  d2   e 1)       e1     g   h

EVF9330-EV

EVF9331-EV

373

340

543

510

45

137.5

217.5

310

525

45

145

285

163.5

7

9

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting cutout in control cabinet


 


 


Installing the basic device

Basic devices in the power range 75 ... 90 kW Important notes

 

4

4.4 4.4.1


 

4.4             Basic devices in the power range 75 ... 90 kW

 

4.4.1         Important notes

The accessory kit is located in the inside of the drive controller.

Remove the cover of the drive controller                                                                                       

 

4.4.2         Mounting with fixing brackets (standard)

Mounting material required from the scope of supply:

 

Description

Fixing bracket

Use

Drive controller fixing

Amount

4

Hexagon head cap screw M8 × 16 mm (DIN 933)

For fixing bracket

8

Washer g 8.4 mm (DIN 125)

For hexagon head cap screw

8

Spring washer g 8 mm (DIN 127)

For hexagon head cap screw

8

 


 


4

4.4 4.4.2

 

Installing the basic device

Basic devices in the power range 75 ... 90 kW Mounting with fixing brackets (standard)


 

Dimensions

 

9300vec134

Fig. 4.4-1       Standard mounting with fixing brackets 75 ... 90 kW

囚    Drive controllers can be mounted side by side without spacing

 


9300 vector

Type

   b1


EVF9332-EV

EVF9333-EV

450

750

680

28.5

393

702

38

285

11

28

18

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting                                     ƒ Attach the fixing bracket to the heatsink plate of the drive controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


4.4-2                                                                      

EDSVF9333V  EN  3.0-06/2005


 


Installing the basic device

Basic devices in the power range 75 ... 90 kW Thermally separated mounting (push-through technique)

 

4

4.4 4.4.3


 

4.4.3         Thermally separated mounting (push-through technique)

 


 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting cutout in control cabinet

For  mounting  in  push-through  technique, the  drive  controller  of type EVF93xx-EV.  In  addition,  the   mounting  set  for   EJ0001  push-through technique is required.

 

Fig. 4.4-2       Dimensions for thermally separated mounting 75 ... 90 kW

 

 

EVF9332-EV

EVF9333-EV

488

450

718

680

49

172.5

295.5

698

49

200

285

164

9

10

1)     For a fieldbus module plugged onto X1, consider mounting space for connecting cables

 

9300 vector

Dimensions [mm]

Type

A1

b1

EVF9332-EV

EVF9333-EV

428.5

660

 


9300 vector frequency inverter 15 ... 30 kW EVF9327-EV, EVF9328-EV, EVF9329-EV
9300 vector frequency inverter 15 ... 30 kW EVF9327-EV, EVF9328-EV, EVF9329-EV
Long press to look detail
Long by picture save/share

9300 vector frequency inverter 15 ... 30 kW EVF9327-EV, EVF9328-EV, EVF9329-EV

INQUIRY

Inquiry MORE+
  • Email *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

We are the world's leading supplier of spare parts for medium voltage drives of various brands

GET IN TOUCH

East Sun Industrial Centre, No 16 Shing Yip Street Kl, Hongkong

Call us : +852 5261 7322

SITEMAP

分类标题

BUSINESS HOURS

Monday to Friday : 9 am to 6 pm

Saturday : 9 am to 12 am

Sunday : Closed Support Hours in 24/7 Everyday

DISCLAIMER:

We are not an authorized distributor, reseller or representative of the following products presented on this website. All Product names and logos throughout this site are trademarks of their respective holders. Use of them DOES NOT imply any affiliation with or endorsement by them.

© 2020 robiconperfectharmony.com site . All rights reserved     Site Map

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.