6RA8081-6DV62-0AA0, 6RA80816DV620AA0 Siemens DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 332A
6RA8081-6DV62-0AA0, 6RA80816DV620AA0 SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 332A
6RA80816DV620AA0 | 6RA80816DV620AA0
Product
Image similar
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 332A controllable: Field rectifier D420/400 MREQ-GEGF6V62 Output: 420 V DC, 400 A
List Price Show prices
Customer Price Show prices
Additional Services
For this product we can offer Services like Spare Part Delivery/Repair/Exchange. You have currently no rights to enter the Service Web Shop for that. For further information & to order this service, please contact your local Spares&Repair Partner
Service & Support (Manuals, Certificates, FAQs...) Download
Image gallery and data for M-CAD and E-CAD (2) (2)
Product data Further Product Information
Product
Article Number (Market Facing Number) 6RA80816DV620AA0 | 6RA80816DV620AA0
Product Description SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 332A controllable: Field rectifier D420/400 MREQ-GEGF6V62 Output: 420 V DC, 400 A
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Price data
Price Group 979
List Price Show prices
Customer Price Show prices
Metal Factor None
Delivery information
Export Control Regulations AL : N / ECCN : N
Standard lead time ex-works 25 Day/Days
Net Weight (lb) 61.729 lb
Packaging Dimension 14.961 x 30.118 x 16.535
Package size unit of measure Inch
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN Not available
UPC 662643931815
Commodity Code 8504409999
LKZ_FDB/ CatalogID D23.1LD
Product Group 4106
Group Code R220
Country of origin China
Compliance with the substance restrictions according to RoHS directive Since: 04/16/2018
Returnable No
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates
Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)
1,2-Benzenedicarboxy... CAS-No. 68515-42-4 > 0, 1 % (w / w)
Classifications
Version Classification
eClass 12 27-02-33-01
eClass 6 27-02-33-01
eClass 7.1 27-02-33-01
eClass 8 27-02-33-01
eClass 9 27-02-33-01
eClass 9.1 27-02-33-01
UNSPSC 15 39-12-20-02
|
Buy product
Quantity
1
1 Piece
Add to cart
You can also add options to the product.
Configure Product Options
2Q units
Armature supply
voltage
Rated
DC current
Rated
DC voltage
Type designation Order number
MLFB
3-ph. 400 V AC 60 A
90 A
125 A
210 A
280 A
400 A
600 A
850 A
1200 A
1600 A
2000 A
3000 A
485 V
485 V
485 V
485 V
485 V
485 V
485 V
485 V
485 V
485 V
485 V
485 V
D485/60 Mre-GeE6S22
D485/90 Mre-GeE6S22
D485/125 Mre-GeE6S22
D485/210 Mre-GeEF6S22
D485/280 Mre-GeEF6S22
D485/400 Mre-GeEF6S22
D485/600 Mre-GeEF6S22
D485/850 Mre-GeEF6S22
D485/1200 Mre-GeEF6S22
D485/1600 Mre-GeEF4S22
D485/2000 Mre-GeEF4S22
D485/3000 Mre-GeEF4S22
6RA8025-6DS22-0AA0
6RA8028-6DS22-0AA0
6RA8031-6DS22-0AA0
6RA8075-6DS22-0AA0
6RA8078-6DS22-0AA0
6RA8081-6DS22-0AA0
6RA8085-6DS22-0AA0
6RA8087-6DS22-0AA0
6RA8091-6DS22-0AA0
6RA8093-4DS22-0AA0
6RA8095-4DS22-0AA0
6RA8098-4DS22-0AA0
3-ph. 480 V AC 60 A
90 A
125 A
210 A
280 A
450 A
600 A
850 A
1200 A
550 V
550 V
550 V
550 V
550 V
550 V
550 V
550 V
550 V
D575/60 Mre-GeE6S22
D575/90 Mre-GeE6S22
D575/125 Mre-GeE6S22
D575/210 Mre-GeEF6S22
D575/280 Mre-GeEF6S22
D575/450 Mre-GeEF6S22
D575/600 Mre-GeEF6S22
D575/850 Mre-GeEF6S22
D575/1200 Mre-GeEF6S22
6RA8025-6FS22-0AA0
6RA8028-6FS22-0AA0
6RA8031-6FS22-0AA0
6RA8075-6FS22-0AA0
6RA8078-6FS22-0AA0
6RA8082-6FS22-0AA0
6RA8085-6FS22-0AA0
6RA8087-6FS22-0AA0
6RA8091-6FS22-0AA0
3-ph. 575 V AC 60 A
125 A
210 A
400 A
600 A
800 A
1100 A
1600 A
2000 A
2200 A
2800 A
690 V
690 V
690 V
690 V
690 V
690 V
690 V
690 V
690 V
690 V
690 V
D690/60 Mre-GeE6S22
D690/125 Mre-GeE6S22
D690/210 Mre-GeEF6S22
D690/400 Mre-GeEF6S22
D690/600 Mre-GeEF6S22
D690/800 Mre-GeEF6S22
D690/1100 Mre-GeEF6S22
D690/1600 Mre-GeEF4S22
D690/2000 Mre-GeEF4S22
D690/2200 Mre-GeEF4S22
D690/2800 Mre-GeEF4S22
6RA8025-6GS22-0AA0
6RA8031-6GS22-0AA0
6RA8075-6GS22-0AA0
6RA8081-6GS22-0AA0
6RA8085-6GS22-0AA0
6RA8087-6GS22-0AA0
6RA8090-6GS22-0AA0
6RA8093-4GS22-0AA0
6RA8095-4GS22-0AA0
6RA8096-4GS22-0AA0
6RA8097-4GS22-0AA0
3-ph. 690 V AC 720 A
1000 A
1500 A
2000 A
2600 A
830 V
830 V
830 V
830 V
830 V
D830/720 Mre-GeEF6S22
D830/1000 Mre-GeEF6S22
D830/1500 Mre-GeEF4S22
D830/2000 Mre-GeEF4S22
D830/2600 Mre-GeEF4S22
6RA8086-6KS22-0AA0
6RA8090-6KS22-0AA0
6RA8093-4KS22-0AA0
6RA8095-4KS22-0AA0
6RA8097-4KS22-0AA0
3-ph. 830 V AC 950 A
1500 A
1900 A
1000 V
1000 V
1000 V
D1000/950 Mre-GeEF6S22
D1000/1500 Mre-GeEF4S22
D1000/1900 Mre-GeEF4S22
6RA8088-6LS22-0AA0
6RA8093-4LS22-0AA0
6RA8095-4LS22-0AA0
3-ph. 950 V AC 2200 A 1140 V D1140/2200 Mre-GeEF4S22 6RA8096-4MS22-0AA0
Type spectrum, ordering information
2.1 Unit order numbers
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619 21
4Q units
Armature supply
voltage
Rated
DC current
Rated
DC voltage
Type designation Order number
MLFB
3-ph. 400 V AC 15 A
30 A
60 A
90 A
125 A
210 A
280 A
400 A
600 A
850 A
1200 A
1600 A
2000 A
3000 A
420 V
420 V
420 V
420 V
420 V
420 V
420 V
420 V
420 V
420 V
420 V
420 V
420 V
420 V
D420/15 Mreq-GeG6V62
D420/30 Mreq-GeG6V62
D420/60 Mreq-GeG6V62
D420/90 Mreq-GeG6V62
D420/125 Mreq-GeG6V62
D420/210 Mreq-GeGF6V62
D420/280 Mreq-GeGF6V62
D420/400 Mreq-GeGF6V62
D420/600 Mreq-GeGF6V62
D420/850 Mreq-GeGF6V62
D420/1200 Mreq-GeGF6V62
D420/1600 Mreq-GeGF4V62
D420/2000 Mreq-GeGF4V62
D420/3000 Mreq-GeGF4V62
6RA8013-6DV62-0AA0
6RA8018-6DV62-0AA0
6RA8025-6DV62-0AA0
6RA8028-6DV62-0AA0
6RA8031-6DV62-0AA0
6RA8075-6DV62-0AA0
6RA8078-6DV62-0AA0
6RA8081-6DV62-0AA0
6RA8085-6DV62-0AA0
6RA8087-6DV62-0AA0
6RA8091-6DV62-0AA0
6RA8093-4DV62-0AA0
6RA8095-4DV62-0AA0
6RA8098-4DV62-0AA0
3-ph. 480 V AC 15 A
30 A
60 A
90 A
125 A
210 A
280 A
450 A
600 A
850 A
1200 A
500 V
500 V
500 V
500 V
500 V
500 V
500 V
500 V
500 V
500 V
500 V
D500/15 Mreq-GeG6V62
D500/30 Mreq-GeG6V62
D500/60 Mreq-GeG6V62
D500/90 Mreq-GeG6V62
D500/125 Mreq-GeG6V62
D500/210 Mreq-GeGF6V62
D500/280 Mreq-GeGF6V62
D500/450 Mreq-GeGF6V62
D500/600 Mreq-GeGF6V62
D500/850 Mreq-GeGF6V6
D500/1200 Mreq-GeGF6V62
6RA8013-6FV62-0AA0
6RA8018-6FV62-0AA0
6RA8025-6FV62-0AA0
6RA8028-6FV62-0AA0
6RA8031-6FV62-0AA0
6RA8075-6FV62-0AA0
6RA8078-6FV62-0AA0
6RA8082-6FV62-0AA0
6RA8085-6FV62-0AA0
6RA8087-6FV62-0AA0
6RA8091-6FV62-0AA0
3-ph. 575 V AC 60 A
125 A
210 A
400 A
600 A
850 A
1100 A
1600 A
2000 A
2200 A
2800 A
600 V
600 V
600 V
600 V
600 V
600 V
600 V
600 V
600 V
600 V
600 V
D600/60 Mreq-GeG6V62
D600/125 Mreq-GeG6V62
D600/210 Mreq GeGF6V62
D600/400 Mreq-GeGF6V62
D600/600 Mreq-GeGF6V62
D600/850 Mreq-GeGF6V62
D600/1100 Mreq-GeGF6V62
D600/1600 Mreq-GeGF4V62
D600/2000 Mreq-GeGF4V62
D600/2200 Mreq-GeGF4V62
D600/2800 Mreq-GeGF4V62
6RA8025-6GV62-0AA0
6RA8031-6GV62-0AA0
6RA8075-6GV62-0AA0
6RA8081-6GV62-0AA0
6RA8085-6GV62-0AA0
6RA8087-6GV62-0AA0
6RA8090-6GV62-0AA0
6RA8093-4GV62-0AA0
6RA8095-4GV62-0AA0
6RA8096-4GV62-0AA0
6RA8097-4GV62-0AA0
3-ph. 690 V AC 760 A
1000 A
1500 A
2000 A
2600 A
725 V
725 V
725 V
725 V
725 V
D725/760 Mreq-GeGF6V62
D725/1000 Mreq-GeGF6V62
D725/1500 Mreq-GeGF4V62
D725/2000 Mreq-GeGF4V62
D725/2600 Mreq-GeGF4V62
6RA8086-6KV62-0AA0
6RA8090-6KV62-0AA0
6RA8093-4KV62-0AA0
6RA8095-4KV62-0AA0
6RA8097-4KV62-0AA0
3-ph. 830 V AC 950 A
1500 A
1900 A
875 V
875 V
875 V
D875/950 Mreq-GeGF6V62
D875/1500 Mreq-GeGF4V62
D875/1900 Mreq-GeGF4V62
6RA8088-6LV62-0AA0
6RA8093-4LV62-0AA0
6RA8095-4LV62-0AA0
3-ph. 950 V AC 2200 A 1000 V D1000/2200 MreqGeGF4V62 6RA8096-4MV62-0AA0
Option Order codes
Armature infeed with extra-low voltage 10 V to 50 V
(possible for units with rated supply voltage ≤575 V
L04
Electronics power supply for connection to 24 V DC L05
Sensor for the air intake temperature L15 2)
Coated modules M08 1)
Nickel-plated copper bars
(for units with aluminum bars as standard, use of nickel-plated copper bars)
M10
Control for switching over the power unit topology for devices connected in parallel and series
This option is described in the application document "12-pulse applications".
S50
1) Coated modules increase the degree of ruggedness with respect to climatic effects:
Relative / absolute humidity 5 % to 95 % / 1 to 29 g/m3 for ambient temperature or cooling medium temperature ≤30 °C
≤ 60 % with the occurrence of SO2 and H2S and/or for ambient temperature or cooling medium temperature 30 °C to 40 °C
Oil mist, salt mist, formation of ice, condensation, dropping, spray, splashing and jet-water not permissible.
2) possible from software release 1.3 HF1 and higher
Ordering information for accessories
Table 2- 5 Order numbers for documentation
Item Order number
Set of manuals, German 6RX1800-0GD00
SINAMICS DCM DC Converter Operating Instructions, German 6RX1800-0AD00
SINAMICS DCM List Manual, German 6RX1800-0ED00
Free Function Blocks manual, German 6RX1800-0FD00
Set of manuals, English 6RX1800-0GD76
SINAMICS DCM DC Converter Operating Instructions, English 6RX1800-0AD76
SINAMICS DCM List Manual, English 6RX1800-0ED76
Free Function Blocks manual, English 6RX1800-0FD76
Set of manuals, French
(includes the Free Function Blocks manual in English)
6RX1800-0GD77
SINAMICS DCM DC Converter Operating Instructions, French 6RX1800-0AD77
SINAMICS DCM List Manual, French 6RX1800-0ED77
Set of manuals, Italian
(includes the Free Function Blocks manual in English)
6RX1800-0GD72
SINAMICS DCM DC Converter Operating Instructions, Italian 6RX1800-0AD72
SINAMICS DCM List Manual, Italian 6RX1800-0ED72
Type spectrum, ordering information
2.4 Ordering information for options and accessories
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619 27
Item Order number
Set of manuals, Russian
(includes the Free Function Blocks manual in English)
6RX1800-0GD56
SINAMICS DCM DC Converter Operating Instructions, Russian 6RX1800-0AD56
SINAMICS DCM List Manual, Russian 6RX1800-0ED56
Set of manuals, Spanish
(includes the Free Function Blocks manual in English)
6RX1800-0GD78
SINAMICS DCM DC Converter Operating Instructions, Spanish 6RX1800-0AD78
SINAMICS DCM List Manual, Spanish 6RX1800-0ED78
Set of manuals, Chinese
(includes the Free Function Blocks Manual in English)
6RX1800-0GD27
SINAMICS DCM DC Converter Operating Instructions, Chinese 6RX1800-0AD27
SINAMICS DCM List Manual, Chinese 6RX1800-0ED27
All documentation in all of the above languages, on DVD 6RX1800-0AD64
Table 2- 6 Order numbers for accessories
Item Order number
Standard CUD retrofit kit
Combination of the spare parts, Standard CUD and connector board
6RY1803-0AA00 +
6RY1803-0GA00
Standard CUD coated retrofit kit
Combination of the spare parts, Standard CUD coated and connector board coated
6RY1803-0AA20 +
6RY1803-0GA20
Advanced CUD retrofit kit
Combination of the spare parts, Advanced CUD and connector board
6RY1803-0AA05 +
6RY1803-0GA00
Advanced CUD coated retrofit kit
Combination of the spare parts, Advanced CUD coated and connector board coated
6RY1803-0AA25 +
6RY1803-0GA20
CBE20 PROFINET 6SL3055-0AA00-2EB0
Memory card (equivalent to spare part for options S01 and S02) 6RX1800-0AS01
Terminal Module TM15 6SL3055-0AA00-3FA0
Terminal Module TM31 6SL3055-0AA00-3AA1
Sensor Module Cabinet-Mounted SMC30 6SL3055-0AA00-5CA2
Mounting kit to increase the degree of protection to IP20 for 15 A to 30 A units 6RX1800-0MA00 3)
Mounting kit to increase the degree of protection to IP20 for 60 A to 280 A units 6RX1800-0MA01 3)
Mounting kit to increase the degree of protection to IP20 for 400 A to 600 A units 6RX1800-0MA02 3)
Mounting kit to increase the degree of protection to IP20 for 720 A to 850 A units 6RX1800-0MA03 3)
SICROWBAR overvoltage protection Depending on unit type 1)
SIMOREG DC-MASTER Converter Commutation Protector Depending on unit type 1)
Firing Unit Trigger-Board 6RY1803-0CP00
Fuses Depending on unit type 4)
Reactors Depending on unit type 2)
RFI suppression filter Depending on unit type 2)
Type spectrum, ordering information
2.4 Ordering information for options and accessories
SINAMICS DCM DC Converter
28 Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
Item Order number
STARTER commissioning tool 6SL3072-0AA00-0AG0
Drive Control Chart (DCC) for SINAMICS 6AU1810-1HA20-1XA0
Drive Control Chart (DCC) for SINAMICS and SIMOTION 6AU1810-1JA20-1XA0
1) Please contact your local Siemens office.
2) Refer to the section titled "Connecting" as well as the catalogs and reference sources specified in this section.
3) The installation instructions are provided on the SINAMICS DCM Documentation DVD under "Accessories"
4) see Chapter "Fuses" as well as the catalogs and reference sources specified in this chapter.
Table 2- 7 Order numbers for the Advanced Operator Panel AOP30
Item Order number
Advanced Operator Panel AOP30 6SL3055-0AA00-4CA4
RS485 connecting cable for connecting the AOP30 to one CUD; 3 m 6RY1807-0AP00
RS485 connecting cable for connecting the AOP30 to two CUDs; 3 m 6RY1807-0AP10
Additional cable lengths can be ordered as option.
When ordering the RS485 cable with option, the suffix "-Z" must be attached to the Order No. followed by the order code
for the required option.
Ordering example for a 35 m long cable:
Order number: 6RY1807-0AP00-Z, order code: K35
Cable length Order code
5 m K05
10 m K10
15 m K15
20 m K20
25 m K25
30 m K30
35 m K35
40 m K40
45 m K45
50 m K50

Copy product links
Long by picture save/share