GenIV Installation, Commissioning, and Maintenance Manual                                           Maintenance

 

Table 4-1: GenIV Spare Parts (for Drives less than or equal to 140A Output, 4160V Output)

 

Spare Part

Item

Part Number

Power Cell*

40A Cell

10000424.040

70A Cell

10000424.070

100A Cell

10000424.100

140A Cell

10000424.140

 

Cell CCB Fuse

1000V, 1A Fuse A1A092604

Cell Input Fuses

Refer to chart in Section

Transformer Air Filters

Door Filter

A1A11006180.01

 

Cell Air Filters

Door Filter

A1A11006180.00

 

 

 

NXG

SBC & Keypad

Adapter

A1A10000623.000M

System I/O Board

A1A10000423.00

BGA

Modulator

A1A10000350.00M

 

 

I/O

Breakout Board

120V I/O

A5E01649325

Signal Control

Board

A1A10000403.01

NXGII Power

Supply

A1A14000461.00

Keypad

A1A460A68.23

24V I/O

A5E01649374

Blower Fuses

8A, 600V AJT A1A089149

Control

Transformer Fuse

Secondary 6A, 600V

A1A081099

Control

Transformer Fuse

Primary 3A, 600V A1A080752 (480V)

Primary 3.5A, 600V

A1A089205 (400V)

Fiber Optic

Fiber Optic Link, 2.9M

A1A10000614.00

Blower

EC Blower

A1A098200 (EBM)

Cell Bypass

Bypass Contactor

A1A10000539.00

Fuse 2A 1200V A1A089592

PCA Bypass Control

A1A3636601.01M

Power Supply

A1A10000484.00

 

Communication Network

Profibus DP

A1A252241.155

Devicenet Profile12 A1A252241.156

 

Modbus Ethernet

A1A252241.157

 

Control Net

A1A252241.158

Modbus +

A1A252241.159

Modbus

A1A252241.160


GenIV Cell Lifter A1A163496.08

 


Maintenance                                           GenIV Installation, Commissioning, and Maintenance Manual

 

Table 4-2: GenIV Spare Parts (for Drives greater than 140A Output, 4160V Output)

 

Spare Part

Item

Part Number

Power Cell*

200A Cell

A1A10000424.200

260A Cell

10000424.260

 

Cell CCB Fuse

1000V, 1A Fuse A1A092604

Cell Input Fuses

 

Refer to Table 4-4

Transformer Air

Filters

 

Door Filter (4160V)

A1A11006181.01

Cell Air Filters

Door Filter

A1A11006181.00

 

 

 

 

 

NXG

SBC & Keypad

Adapter

A1A10000623.000M

 

System I/O Board

A1A10000423.00M

BGA

Modulator

A1A10000350.00 M

 

 

I/O

Breakout Board

 

120V I/O

A5E01649325

Signal Control

Board

A1A10000403.01M

NXGII Power

Supply

A1A14000461.00M

Keypad

A1A460A26.23

24V I/O

A5E01649374

Communications Board

A1A363818.00M

Blower Fuses

8A, 600V AJT A1A089149

Control

Transformer

Secondary Fuse

6A, 600V

A1A081099

Control

Transformer Fuse

 

480V Primary

3A, 600V,

A1A080752

 

400V Primary

3.5A, 600V

A1A089205

Fiber Optic

Fiber Optic Link, 3.4m

A5E01437712

Blower

EC Blower

A1A0100118

 

Cell Bypass

Bypass

Contactor Assembly A1A10000539.00

Fuse 2A 1200V A1A089592

Bypass Control PCA

A1A363662.01M

Power Supply

A1A10000484.00

 


GenIV Installation, Commissioning, and Maintenance Manual                                           Maintenance

 

 

Spare Part

Item

Part Number

 

Communication Network

Profibus DP

A1A252241.155

Devicenet Profile12 A1A252241.156

 

Modbus Ethernet

A1A252241.157

 

Control Net

A1A252241.158

Modbus +

A1A252241.159

Modbus

A1A252241.160

 

Hall Effect

500A HECT

A1A089836

 

 

Input CT

CT 50:5

A1A091705

CT 75:5

A1A091706

CT 100:5

A1A091707

CT 150:5

A1A091708

CT 200:5

A1A091709

CT 250:5

A1A091710

CT 300:5

A1A091711

CT 400:5

A1A091712

CT 500:5

A1A091713

CT 600:5

A1A091714

 

 

 

 

Input

Attenuator

2.4 kV

A1A164877.00

3.0kV

A1A164877.01

3.3kV

A1A164877.02

4.16kV

A1A164877.03

4.8 kV

A1A164877.04

6.0 kV

A1A164877.05

6.6 kV

A1A164877.06

6.9 kV

A1A164877.07

7.2 kV

A1A164877.08

8.4 kV

A1A164877.09

10.0 kV

A1A164877.10

11.0 kV

A1A164877.11

12.0 kV

A1A164877.12

12.5 kV

A1A164877.13

13.2 kV

A1A164877.14

13.8 kV

A1A164877.15

Output

Attenuator

4160V

A1A164877.03

Cell Lifter

GenIV Cell Lifter A1A163496.08

 


Maintenance                                           GenIV Installation, Commissioning, and Maintenance Manual

 

Table 4-3: GenIV Spare Parts (for Drives greater than 140A Output, 6600V Output

 

Spare Part

Item

Part Number


Power Cell*

40A Cell

A1A10000424.040

70A Cell

A1A10000424.070

100A Cell

10000424.100

140A Cell

10000424.140

200A Cell

10000424.200

260A Cell

10000424.260

Cell CCB Fuse

1000V, 1A Fuse A1A092604


Cell Input Fuses

Refer to Table 4-4


Transformer Air Filters

Door Filter A5E01679467

Cell Air Filters

Door Filter (6600V) A5E01679468

 

 

 

 

NXGII Control

 

SBC & Keypad Adapter A1A10000623.000M

 

System I/O Board

A1A10000423.00M

BGA

Modulator

A1A10000350.00 M

 

 

I/O

Breakout Board

 

120V I/O

A5E01649325

Signal Control

Board

A1A10000403.01M

Power Supply

A1A14000461.00

Keypad

A1A460A26.23

24V I/O

A5E01649374

Communications Board

A1A363818.00M

Fiber-Optic Link Board (FOLB)

A1A461D85.00M

Blower Fuses

8A, 600V AJT A1A089149

OR

10A, AJT

A1A089150

Blower Circuit Breakers

(Optional)

3P, 10A, 600V

A5E01459444


Control

Transformer

Secondary Fuse

6A, 600V

A1A081099

Control

Transformer Fuse

 

480V Primary

3A, 600V

A1A080752

 

400V Primary

3.5A, 600V

A1A089205

Control

Transformer

Primary

Circuit Breaker (Optional)

 

2P, 3A,480V

A1A0101400

Fiber Optic

Fiber Optic Link, 10m A1A085868

Blower

60” Transformer Cabinet

EC Blower

A1A098200

Cell Section & 80” Transformer Cabinet

EC Blower

A1A0100118

 

Cell Bypass

Bypass

Contactor

A1A260934.00

Fuse 2A 1200V A1A089592

Bypass Control PCA A1A363662.01M

Bypass Power Supply A1A10000484.00

 

Communication Network

Profibus DP

A1A252241.155

Devicenet Profile12 A1A252241.156

 

Modbus Ethernet

A1A252241.157

 

Control Net

A1A252241.158

Modbus +

A1A252241.159

Modbus

A1A252241.160

 


GenIV Installation, Commissioning, and Maintenance Manual                                           Maintenance

 

 

Spare Part

Item

Part Number


 

Hall Effect

200A, HECT

A1A089834

500A, HECT

A1A089836

 

 

Input CT

CT 50:5

A1A091705

CT 75:5

A1A091706

CT 100:5

A1A091707

CT 150:5

A1A091708

CT 200:5

A1A091709

CT 250:5

A1A091710

CT 300:5

A1A091711

CT 400:5

A1A091712

CT 500:5

A1A091713

CT 600:5

A1A091714

 

 

 

 

Input

Attenuator

2.4 kV

A1A164877.00

3.0kV

A1A164877.01

3.3kV

A1A164877.02

4.16kV

A1A164877.03

4.8 kV

A1A164877.04

6.0 kV

A1A164877.05

6.6 kV

A1A164877.06

6.9 kV

A1A164877.07

7.2 kV

A1A164877.08

8.4 kV

A1A164877.09

10.0 kV

A1A164877.10

11.0 kV

A1A164877.11

12.0 kV

A1A164877.12

12.5 kV

A1A164877.13

13.2 kV

A1A164877.14

13.8 kV

A1A164877.15

Output

Attenuator

6600V

A1A168477.06

Cell Lifter

GenIV Cell Lifter A1A163496.08

*  Customer may request IGBTs, diode rectifiers, and Cell Control Boards rather than a complete spare cell. Contact Siemens for further information regarding individual cell P/Ns.

 

Note: Unless notified differently by Siemens, ALWAYS replace components with the same P/N and revision level.

 

 

4.4 Basic Rules for Repairing Harmony Cells

Cell failures or component failures should be reported to both the Quality Group and Product Development at Siemens.

Always refer to the latest BOM and Assembly Drawings for approved component Part Numbers and procedures when repairing any cell. Failure to use components other than those listed in the BOM may result in poor cell   performance or further failures.

 

Warning! It is imperative to follow these rules for repairing Harmony Cells.

1.    Never parallel or series non-identical manufactures part numbers (or Siemens LD A MDIT Numbers) for IGBTs or Electrolytic Capacitors in the same power cell.

2.    Never substitute a non-specified CCB/GCB/SMPS board (or any specified component or subassembly) without formal approval from the Product Development Group.

3.    Never change an input power fuse(s) without first determining the root cause for the fuse operation. Fuses are not designed to protect components in the Power cell against overload. If a fuse(s) is open, there is


Maintenance                                           GenIV Installation, Commissioning, and Maintenance Manual

 

usually a component failure within the cell. Re-application of rated power may cause catastrophic damage. Always inspect the related transformer winding and cell before replacing fuses.

 

Note: In cases where the latest BOM specifies obsolete components and the substitution of an

alternative is not available, contact the Siemens LD A Product Development Group for assistance. In such events, Product Development may suggest alternative components, only after sufficient technical review and verification.

Refer to Table 4-4 to view which fuses are approved for GenIV use:

Table 4-4: Power Cell Fuses

 

 

Power Cell

Rating Volts, Cell Amps Siemens P/N

040

070

100

140

200

260








Bussman

1000V,100A

A1A099725

1000,160A

A1A099726

1000V, 200A

A1A099727

1000V, 250A

P/N 099728

1250V, 450A

A1A0100500

1100V, 500A

A1A0100503

Ferraz

1000V,100A

A1A099717

1000,160A

A1A099718

1000V, 200A

A1A099719

1000V, 250A

P/N 099720

1300V, 450A

A1A0100502

1200V, 500A

A1A0100505

Siba

1000V,125A

A1A099721

1000,200A

A1A099722

1000V, 225A

A1A099723

1000V, 280A

P/N 099724

1250V, 450A

A1A0100501

1100V, 500A

A1A0100504

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.4.1     How To Remove Harmony Power Cells

To Remove the Power Cell:

1.    Power down the GenIV System, following the standard shut-down procedure shown in Section 1.4.

2.    Open the doors to access the power cells.

3.    Make sure that the DC bus LED (labeled “Charge LED” - see Section 1.4), located on the Cell Control Board (CCB), is off. Then wait an extra minute before proceeding.

4.    Remove the fiber optic from the CCB as shown below.

 

 

5.    Grab the two locking latches and pull down to a horizontal position to release the power cell.

 

Note: When the latches are pulled down to a horizontal position, the power cell will move forward approximately 1/2 inch.

 


GenIV Installation, Commissioning, and Maintenance Manual                                           Maintenance

 

 

 

 

 

 

 

 

 

 

 

4


Maintenance                                           GenIV Installation, Commissioning, and Maintenance Manual

 

6.    Still holding onto the latches, pull the power cell approximately one-third of the way out of its slot as shown next. Do not lift up or pull down on the cell, but rather let it slide on the polyethylene-coated mounting rails:

 

 

 

 

 

 

 

4

 

 

 

 

 

7.    Using the Siemens cell lifter (Siemens P/N A1A163496.08)out of its slot and onto the lifter, as shown below:

 

 

 

 

 

Note: It is good practice to not run the system with one of the cells removed.

 


 

 

4.4.3     How to Install Harmony Power Cells

To Install the Power Cell:

1.    Using the Siemens cell lifter (P/N A1A163496.08), line up the power cell with its slot.

2.    Push the cell into its slot. Do not lift up on the cell, but instead let it slide in on the polyethylene-coated mounting rails.

3.    Make make sure that the cell latches are above the ledge of the cell rail, and align the locking latches with the corresponding rail notches, as shown below:

 

 


Maintenance                                           GenIV Installation, Commissioning, and Maintenance Manual

 

4.    Push up on the latches until they are vertical:

 

 

 

 

 

 

 

 

4

 

 

 

 

5.    Reinstall the Fiber Optic:

 

 


A1A091705, A1A091706, A1A091707, A1A091708, A1A091709, A1A091710, A1A091711, A1A091712, A1A091713, A1A091714
A1A091705, A1A091706, A1A091707, A1A091708, A1A091709, A1A091710, A1A091711, A1A091712, A1A091713, A1A091714
Long press to look detail
Long by picture save/share

A1A091705, A1A091706, A1A091707, A1A091708, A1A091709, A1A091710, A1A091711, A1A091712, A1A091713, A1A091714

INQUIRY

Inquiry MORE+
  • Email *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

We are the world's leading supplier of spare parts for medium voltage drives of various brands

GET IN TOUCH

East Sun Industrial Centre, No 16 Shing Yip Street Kl, Hongkong

Call us : +852 5261 7322

SITEMAP

分类标题

BUSINESS HOURS

Monday to Friday : 9 am to 6 pm

Saturday : 9 am to 12 am

Sunday : Closed Support Hours in 24/7 Everyday

DISCLAIMER:

We are not an authorized distributor, reseller or representative of the following products presented on this website. All Product names and logos throughout this site are trademarks of their respective holders. Use of them DOES NOT imply any affiliation with or endorsement by them.

© 2020 robiconperfectharmony.com site . All rights reserved     Site Map

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.