Cooling fan for inverter 3BHB027324R2010, 3BHB027324R0080, FAN, CENTRIFUGAL, R3G500-RA25-01, EBM, 2650W, 1700RPM, VENTILADOR CENTRFUGO, ABB
Cooling fan for inverter 3BHB027324R2010, 3BHB027324R0080, FAN, CENTRIFUGAL, R3G500-RA25-01, EBM, 2650W, 1700RPM, VENTILADOR CENTRFUGO, ABB
| Situation: | Material code: | Material description: | PM/MTO/MTS-kit code effected: | KIT description: | ||
| Gate Driver Board: | ||||||
| ACS1000 | 3BHE022333R0101 | GATE DRIVER BOARD | ||||
| ACS1000 | 3BHB045647R0005 | PM Kit for 24x 51mm IGCTs - GV C713 A101 | ||||
| ACS1000 | 3BHB045668R0006 | UG Kit for 51mm IGCT - GV C713 A101 | ||||
| ACS5000 | 3BHE024415R0101 | GATE DRIVER BOARD | ||||
| ACS800-01 | 68262402 | RINT5211C | ||||
| ACS800 MD DriveSecti | 68449022 | ACHM-01C | ||||
| ACS800-11 | 68639875 | GINT6611C SP KIT | ||||
| IGCTs | ||||||
| ACS5000 | 3BHB018104R0001 | RC-IGCT 5SHX 0660F0002 | ||||
| ACS5000 | 3BHB020538R0001 | RC-IGCT 5SHX 1060H0003 | ||||
| ACS2000 | 3BHB020684R0001 | IGBT Module | ||||
| IGBT kits | ||||||
| ACS800 | 68569591 | IGBT KIT | ||||
| ACS800 | 64783831 | IGBT MODULE KIT | ||||
| ACS880 | 3AXD50000007341 | IGBT MODULE | ||||
| ACS880 | 3AXD50000158799 | IGBT MODULE KIT | ||||
| ACS880 | 3AXD50000007342 | IGBT MODULE | ||||
| ACS880 | 3AXD50000158898 | IGBT MODULE KIT | ||||
| Phase modules ACS2000 | ||||||
| ACS2000 | 2UBA001210R0040 | PHASE MODULE 4MVA | ||||
| ACS2000 | 2UBA001210R0130 | PHASE MODULE FRAME 3 R0 | ||||
| ACS2000 | 3BHB024711R0020 | PHASE MODULE 3X47UF | ||||
| ACS2000 | 3BHB028673R0010 | PHASE MODULE FRAME 2 R0 | ||||
| Fans | ||||||
| ACS550 | 3AUA0000059271 | FAN (AXIAL) | ||||
| 3BHB027324R2010 | FAN, CENTRIFUGAL | 3BHB040100R0028 | ||||
| Phase modules ACW600 | ||||||
| ACW600 | 3AUA0000026781 | ACW64413906-MD-KIT+V991 | ||||
| ACW600 | 42004294 | PHASE MODULE KIT, U/W-PHASE | ||||
| ACW600 | 42003475 | ACW64413906-MD-KIT+V991 | ||||
| ACW600 | 42004293 | PHASE MODULE KIT, U/W-PHASE | ||||
| ACW600 | 42004294 | PHASE MODULE KIT, U/W-PHASE |
R3G500-RA25-01 Translation of the original operating instructions 3.2 Nominal data Motor M3G150-FF Phase 3~ Nominal voltage / VAC 400 Nominal voltage range / VAC 380 .. 480 Frequency / Hz 50/60 Type of data definition ml Speed / min-1 1700 Power input / W 2650 Current draw / A 4 Min. ambient temperature / °C -25 Max. ambient temperature / °C 60 ml = Max. load · me = Max. efficiency · fa = Running at free air cs = Customer specs · cu = Customer unit Subject to alterations 3.3 Data according to ErP directive Installation category A Efficiency category Static Variable speed drive Yes Specific ratio* 1.01 * Specific ratio = 1 + pfs / 100 000 Pa Actual Request 2013 Request 2015 Overall efficiency ηes / % 63.3 52 56 Efficiency grade N 69.3 58 62 Power input Ped / kW 2.67 Air flow qv / m³/h 6845 Pressure increase total psf / Pa 842 Speed n / min-1 1710 Data definition with optimum efficiency. The ErP data is determined using a motor-impeller combination in a standardised measurement configuration. 3.4 Technical features Mass 22.8 kg Size 500 mm Surface of rotor Coated in black Material of electronics housing Die-cast aluminium Material of impeller PP plastic Number of blades 7 Direction of rotation Clockwise, seen on rotor Type of protection IP 54 Insulation class "F" Humidity class F4-1 Mounting position Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharge holes Rotor-side Operation mode S1 Motor bearing Ball bearing Technical features - Output 10 VDC, max. 10 mA - Output 20 VDC, max. 50 mA - Output for slave 0-10 V - Operation and alarm display - Input for sensor 0-10 V or 4-20 mA - External 24 V input (programming) - External release input - Alarm relay - Integrated PID controller - Motor current limit - PFC, passive - RS485 MODBUS RTU - Soft start - Control input 0-10 VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Over-temperature protected electronics / motor - Line undervoltage / phase failure detection Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) <= 3.5 mA Electrical leads Via terminal box Motor protection Reverse polarity and locked-rotor protection Protection class I (if protective earth is connected by customer) Product conforming to standard EN 61800-5-1; CE Approval UL 1004-7 + 60730; EAC; C22.2 Nr.77 + CAN/CSA-E60730-1 For cyclic speed loads, note that the rotating parts of the device are designed for maximum one million load cycles. If you have specific questions, contact ebm-papst for support. 3.5 Mounting data ; Secure the mounting screws against accidentally coming loose (e.g. by using self-locking screws). Strength class for mounting screws 8.8 You can obtain additional mounting data from the product drawing if necessary. 3.6 Transport and storage conditions ; Use the device in accordance with its protection type. Max. permissible ambient motor temp. (transp./ storage) +80 °C Min. permissible ambient motor temp. (transp./storage) -40 °C I