Robicon Perfect Harmony Medium Voltage AC Drives

Robicon Perfect Harmony Medium Voltage AC Drives

Robicon Perfect Harmony

Medium Voltage AC Drives

industrial POWER CONTROL

Unlike conventional power control

technology, the Perfect Harmony AC

drive is easy to use and maintain. Plus,

the soft start features of the Perfect

Harmony decrease stresses that can

limit the life of your equipment.

The Business Behind a Variable

Frequency Drive

If you haven't installed a VFD yet, you're

letting thousands of dollars of energy

costs eat away at your bottom line

every month. 

The culprit? An inefficient process. 

The US Department of Energy (DOE)

says that industrial motors consume

over a billion kilowatt hours of energy

each year – 50 percent of the world's

energy usage. System improvements

such as improved sizing and proper

matching to load, use of more efficient

drive trains, and use of adjustable speed

drives will help drive energy usage

down, according to the DOE. That

means the right drive helps you drive

cost out of your operation. 

Siemens has the largest installed base 

of medium voltage AC drives. We serve

all segments of the market, as we’re the

only company that offers drives from

300 to 160,000 HP (225 to 120,000 kW). 

Selecting the right drive system for 

your application – no matter what the

industry or application – means your

maintenance costs go down while 

your production numbers stay high.

The right system even means lower

operating costs when your new drive

allows you to build a more energy

efficient process.

The Perfect Harmony drive from

Siemens is the world's best-selling

medium voltage AC drive. And there 

is good reason it should be your drive.

For most applications, installing a

Perfect Harmony Variable Frequency

Drive can immediately slash energy

costs, improve productivity and 

protect the environment. 

Rely on the Number One Source for Medium Voltage AC Drives 

Getting the Right Service and

Support Helps, Too

The Siemens difference is apparent 

from the first meeting. Our experts 

have tailored thousands of systems. 

So you’ll see right away that we have 

the right level of power conversion

experience to help select the right 

drives to streamline your process. 

1

The Perfect Harmony of Performance, Process and Technology

Setting the Standard in Power

Conversion

Since its introduction in 1994, the

Perfect Harmony drive has revolutionized

power conversion and continues to set

industry standards for reliability and

innovation. However, advances are 

made without “reinventing the wheel”

like other drive manufacturers. We 

have maintained the Perfect Harmony’s 

core topology and continue to advance

its capability, ensuring life-cycle product

support. The Perfect Harmony of today

represents an evolution founded on

experience garnered from our huge

installation base.

Designed for Maximum

Versatility, Efficiency and

Reliability

The patented, integrated design of 

the Perfect Harmony drive ensures 

a level of reliability, efficiency and

versatility that is unmatched in the

power controls industry. The Perfect

Harmony is designed to withstand

failures that would overwhelm

conventional drive systems.

Proven Solutions for Every

Industry 

The most successful medium voltage

drive ever built, the Perfect Harmony

is used in thousands of applications

around the world. From water 

treatment to power generation to oil 

and gas production, we can provide a

custom-engineered Perfect Harmony

drive to maximize your process.

2

What is an Integrated Variable Frequency Drive (VFD)?

A traditional VFD features up to five separate components, such as harmonic filter, power factor correction, transformer,

power converter, and motor filter. However, the Perfect Harmony’s topology integrates these elements so an isolation

transformer and power converter are the only major components required. The integrated system allows for quick, easy and 

less expensive installations and start-ups. Shortening your outages and process downtime gives you more project flexibility.

Designed for Maximum Versatility, Efficiency and Reliability

Perfect Harmony Topology Structure

Isolation 

Transformer

Power

Converter

Harmonic

Filtering

Power Factor

Correction

Motor 

Filter

Isolation 

Transformer

Power

Converter

Conventional

VFD

Perfect

Harmony 

Integrated

VFD

In the Perfect Harmony, a series of low voltage cells are linked together to build the medium

voltage power output of the drive system. This patented configuration gives the Perfect Harmony

many advantages when it comes to maintenance, power quality and reliability. It also provides the

basis for one of its most most important advantages – increased reliability through the advanced

cell bypass option.

3

4160 VOLT DRIVE TOPOLOGY 6600 – 7200 VOLT DRIVE TOPOLOGY

4

The Perfect Harmony can accept many

different input voltages and can provide

motor output voltages up to 13,800 

volts, putting it in a class by itself.

Efficiency

The integrated Perfect Harmony

maximizes efficiency in a number of

critical areas.Integration helps provide

quick and reliable start-ups, a smaller

footprint and allows for the addition 

of power conversion redundancy. It 

all adds up to a smaller, more efficient 

and reliable system. 

Versatility

The proven technology of the Robicon

Perfect Harmony drive meets the needs 

of customers in many industries, from 

water treatment to energy production to

chemical processing. Siemens is the only

industrial power controls manufacturer 

to offer this level of system versatility 

to its customers.

And when it comes to retrofits, the Perfect

Harmony upholds its reputation as the

world’s most versatile medium voltage

drive. The Perfect Harmony is compatible

with existing motor systems, regardless

of age, brand or voltage/frequency – even

synchronous motors.

You can be sure that the Perfect Harmony

is compatible with your power system as it

meets the most stringent IEEE 519 1992

requirements for voltage and current

harmonic distortion.

The Perfect Harmony exceeds .95 power factor at normal operating speeds without

external power-factor correction capacitors. It also provides more than 98 percent

VFD efficiency and 97 to 96.5 percent total drive system efficiency.

VFD

Efficiency (%)

Total Drive System

Efficiency (%)

(VFD &

Transformer)

Load (%) Power Factor

25 97.5 - 93.4 97.0 - 96.5 .96 50 98.0 - 95.0 97.2 - 96.8 .96 75 98.5 - 97.5 97.2 - 96.8 .96 100 98.6 - 98.0 97.0 - 96.5 .95

Efficiency and power factor values are based on centrifugal load characteristics

for torque and speed.

System Performance

5

Harmonic Comparison of Typical 1,000 HP

12-Pulse PWM Inverter vs. Perfect Harmony Series

1,100KVA, 5.75% Impedance Source

 18 Pulse, Multi-level PWM 

Source Current

Source Voltage

 18 Pulse, Multi-level PWM 

Source Current u u

Source Voltage o V e

SCR Converter CSI 

without Power Factor

Correction Capacitors

Robicon Perfect Harmony

10 20 30 40 50 60 70 80 90 100

50

55

60

65

70

75

80

85

90

95

100

Percent Speed

Total power factor includes distortion and displacement power factor.

CSI PWM or LCI

 Perfect Harmony

10 20 30 40 50 60 70 80 90 100

80

82

84

86

88

90

92

94

96

98

100

Percent Load

System efficiency includes isolation transformer, harmonic filter,

power factor correction and drive.

 Unfiltered, 12-Pulse Input Diode Rectifier 

Source Current

Source Voltage S e t

 Unfiltered, 12-Pulse Input Diode Rectifier 

Source Current u C n

Perfect Harmony Series Waveform

less than 3% total voltage distortion

less than 5% total current distortion

Meets IEEE 519-1992 at the input to the isolation transformer

12-Pulse Harmonic Waveform

5.9% total voltage distortion

8.8% total current distortion

Clean Power Input

The Robicon Perfect Harmony drive meets the most stringent harmonic requirements for voltage 

and current distortion.

• Protects other on-line equipment from harmonic disturbance (computers, telephones, lighting ballast)

• Prevents “cross-talk” with other sensitive control and variable frequency drives

• Avoids costly harmonic filters and associated resonance problems

Typical System Efficiency

Robicon “Perfect Harmony” Series vs. CSI PWM or LCI

Measured Power Factor

Power Factor (%)

Efficiency (%)

Power Quality Output

• No common mode motor insulation stress

– Perfect Harmony includes an isolation transformer integral in common mode dissipation

– Motor does not require 10 to 13 kV insulation

• Drive is compatible with both new and existing 1.0 service factor induction or synchronous motors from any manufacturer 

without any special design considerations

• No significant VFD induced torques pulsations – even at low speeds

• No need for expensive flexible couplings

• No additional VFD induced motor heating

• No cable length restrictions

• Allows standard motor insulation – decreasing the motor insulation requirements to less than an across-the-line start motor

Perfect Harmony

Output Waveforms at 100% Speed

Perfect Harmony

Output Waveforms at 50% Speed

CELL 1

CELL 2

CELL 3

COMPOSITE

6

Multi-Level, Pulse-Width Modulated,

Output-Voltage Waveform

Maximizes Uptime Through Redundancy and ProToPS™ Process Control

Reliability

The reliability of the Perfect Harmony 

drive is second to none due to Siemens’

common-sense approach to component

selection and design. Traction grade

insulated Gate Bipolar Transistors (IGBTs)

form the backbone of the Perfect Harmony

drive. Built-in high volumes and serving

as a proven power device across the

industrial power control industry, IGBT

technology has been in existence for

more than a decade. The stability and

availability of IGBTs give you reliable,

long-term, life-cycle confidence. But

that’s just the start of our forward￾thinking design.

Advanced Cell Bypass

The Perfect Harmony is engineered 

to withstand failures that would over￾whelm conventional drives because

we’ve added redundancy options into

the system. Our patented, cell-based

configuration maximizes uptime and

simplifies modifications. Through a

redundant bypass control that is

completely separated from each power

cell, the Perfect Harmony ensures

automatic bypass of a failed power 

cell in 250 milliseconds (less than 1/4 

of a second).

Another feature that bolsters the Perfect

Harmony’s reliability is its control strategy.

Our Process Tolerant Protection Strategy

(ProToPS™) is a groundbreaking process

control system available exclusively from

Siemens. Instead of tripping the drive and

automatically shutting down the system

due to a malfunction, ProToPS provides 

a hierarchical system of warnings. This 

control strategy allows time to evaluate 

the situation and respond appropriately

to avoid a system shutdown. ProToPS has

proved invaluable for many of our Perfect

Harmony customers, including strategic

power plants, refineries, water and

wastewater facilities, and process plants.

Factory System Test

Upon delivery, you can be confident 

that the Perfect Harmony will get your

process running because we have the

ability to test every product as a

complete system at full load. At our

factory, we test every transformer and

power converter together so that any

imperfections can be identified and

corrected before the product is shipped.

In addition, factory testing allows

accurate efficiency measurements. We

also verify sequence of operation and

protection to ensure that the Perfect

Harmony system matches your needs.

Advanced Power Cell Bypass Advanced Power Cell Bypass Advanced Power Cell Bypass

Protecting Process Quality

If a power cell is bypassed, there is minimal degradation of the motor’s

output power quality, as the Perfect Harmony’s advanced power cell 

bypass system ensures that your process is uninterrupted.

Advanced Cell Bypass Results

Percent of

Nominal 

Voltage

During Dip

Duration of Dip in Milliseconds

Voltage Dip Withstand Capability during 

Full Load, Nominal Voltage

The Perfect Harmony operates continuously, 

even during a 30 percent voltage dip.

Voltage Dip Withstand Capability 

Equivalent Circuit of 

4-Cell Generation3

Harmony Drive 

with all cells 

in service

4160 Volts Typ.

(Line-to-Line)

Equivalent Circuit of 

4-Cell Harmony Drive 

with Cell A4 out 

of service

• Unbalance after 

loss of A4 

(not acceptable)

Equivalent Circuit 

of 4-Cell Harmony

Drive with Cell A4 

out of service

• Neutral Point Shift:

Balance Restored 

after loss of A4 by 

adjusting angles.

Maximum Voltage =

87.5% x 440V = 

3850V

7

8

Easy Set-up and Control

• Easy to use high function key pad on the door

• Touch-screen interface on door also available

• Auto-tune feature shortens start-up and guarantees 

operational efficiency 

• Drive tool runs on PC’s which can interface through 

the RS 485 or ethernet ports that are standard

• Other protocols supported:

Modbus PlusTM

DeviceNet Profile 12TM

ControlNetTM

PROFIBUS DPTM

Other connectivity as required by the user

Control Drive Tool

• Provides windows-based graphical 

user interface

• Has full functionality

• Same menu structure as 

keypad interface

Edit a Parameter

Menu Structure

Window

Graphic Window

Drive Status

Window

• • • •

Trusted in the Most Demanding Applications

The Perfect Harmony is regularly applied 

by the most reliability and quality 

conscious industries and their most

demanding applications.

Oil and Gas

ESP's – offshore and onshore for powering

electrical submersible pumps at cable 

lengths up 35 km (22 miles) without

complicated output filters.

High Speed Compressors - process critical

high speed applications for liquefied 

natural gas and refineries consistently 

choose the Perfect Harmony because it

delivers sinusoidal power at output

frequencies of 330 hertz and beyond

making these systems less complicated,

more efficient and lowering their life 

cycle maintenance.

Power Generation

Induced and forced draft boiler fans –

when the power has to be delivered 

the Perfect Harmony has been the

overwhelming choice of the U.S. power

generation market because of the

Siemens’ engineering expertise and 

the remarkable reliability that the each

and every installation has shown.

Water

In more than 20 countries, the Perfect

Harmony drive is the medium voltage

drive of choice for all types of critical

clean water and wastewater pumping

applications.

Adding to the versatility of the Perfect

Harmony drive, it is available with 

forced-air-cooling (bottom) or self￾contained, closed-loop, water-cooling

(top). Redundant pumps are standard 

on water-cooled units. Redundant

blowers are a standard option for

air-cooled units. The multi-cell design

allows quick rack in/out of power cells,

making maintenance of the Perfect

Harmony very quick and simple. A

hydraulic “cell lifter cart” is an option

for larger cell designs.

9

Through Siemens’ alliances with 

ship owners, designers and leading

component suppliers, we can provide

comprehensive electrical systems for all

types of marine applications, including

complete ship propulsion and thruster

systems for merchant, naval and

scientific ships; drilling and exploration

platforms; passenger ships; and

waterway ferries.

10

Marine

The Perfect Harmony helps our marine

customers reduce costs and enhance

power quality and reliability, while

maximizing space. Additionally, the

Perfect Harmony offers regeneration

capability that many marine customers

demand. Through Siemens’ alliances

with ship owners, designers and leading

component suppliers, we can product

comprehensive electrical systems for 

all types of marine applications.

Paper

Through an advanced control strategy

called sensorless or closed-loop 

vector control, the Perfect Harmony 

drive provides precise torque and 

speed control to a wide range of

demanding applications in the pulp 

and paper industry.

At Siemens, we lead the way with

industry “firsts” in medium voltage

drive technology. Since its introduction

in 1994, the Perfect Harmony drive has

set the standard for medium voltage

technology and continues to innovate.

We constantly solicit customer

feedback and use it to guide product

enhancements. Advances, however,

are made without “reinventing the

wheel.” While others change their 

drive topology, Siemens maintains 

the same topology from generation 

to generation. Our customers have 

the option to easily upgrade their

drives with the latest available

technology and features. By keeping

the same topology, our customers 

see a reduction in maintenance and

spare parts, as well as an increase in

quality and reduced life-cycle costs. 

Setting the Standard in High-Power Conversion

1994 • Developed cell-based modular technology, making medium 

voltage drives easier to scale and service, while providing a 

smaller footprint

• First IGBT-based drive at medium voltage

• First fully integrated medium voltage drive to meet all IEEE 519

compliance standards without optional equipment

• First filterless, standard, motor-compatible, medium voltage drive

• First extended cable-length medium voltage drive to power an 

electrical submersible pump motor

1995

• First IGBT-based 

6.6 kV drive without 

an output transformer

1996

• First IGBT-based 

drive above 10000

horsepower

(7500 kW)

11

A History of Continuous Improvement

Siemens has consistently led the 

industry in innovation and quality. 

As power switching device technology

advances and increases output voltage

capability, Siemens improves each

generation of the Perfect Harmony in

three key areas: fewer parts, increased

efficiency and a smaller drive footprint.

Moving forward, Siemens will remain

on the leading edge of medium voltage

technology with the following features 

on future Perfect Harmony drives:

• Intuitive interface systems to make

the Perfect Harmony drive more

user friendly

• Installation wizards for quick and

easy start-up

Cinergy Corporation Inc., the

largest non-nuclear electric

supplier in the U.S., is improving

the efficiency of its Cinergy/PSI

Gibson Generation Station in

Owensville, Ind., by installing 15

sets of 6600 V Perfect Harmony

drives and Robicon motors as part

of an environmental compliance

project. The total capacity of the

new drives and motors will be

more than 150,000 HP, which will

contribute to the site’s overall

capacity of 3,380 megawatts.

Gibson Station is the third 

largest coal-fired generating

station in the country, generating

approximately 20,000,000 net

megawatt hours annually.

• Remote monitoring and control 

to allow customers or Siemens 

to operate the drive, manage its

performance or diagnose service

concerns from any global location

• Intelligent diagnostics to empower

the Perfect Harmony drive to

independently and automatically

correct service concerns

• Parallel redundant control systems to

provide peace of mind to customers

requiring maximum reliability through

redundancy of all drive functions to

help prevent disruptions

Siemens’ investments in emerging

technologies will culminate as these 

features are introduced in upcoming

generations of the Perfect Harmony drive.

1998

• First drive to offer a

process tolerant

protection strategy

(ProToPS™)

• 500th Perfect 

Harmony drive

installed

1999

• First drive to provide

process-transparent, 

cell-bypass capability 

and neutral-point shift

2000

• First voltage-fed drive to

operate a medium voltage

synchronous motor

2001

• 1000th Perfect Harmony

drive installed

2002

• 1500th Perfect Harmony

drive installed

2003

2004

• Largest pulse width 

modulated drive ever 

built – 80,000 HP

2005

• Introduced the 

smallest footprint

medium voltage 

VFD in the 

world – Robicon

MicroHarmony 

• First high voltage 13.8 kV 

drive capable of operating

motors from 4000 HP to 

90000 HP (3000 kW – 

67000 kW), connected 

direct at 13.8 kV

12

Protecting Our Customers’ Investments with Superior Service and Support

Siemens’ service and support 

network is never more than a phone

call away. Representatives are ready 

24 hours a day, seven days a week, 

to assist customers with immediate

technical support geared to handle

every phase of installation, startup,

maintenance and troubleshooting.

Our services include: 

• Around-the-clock field service 

• Preventative maintenance 

• Product refurbishment 

• Training 

• After-market spare parts 

• Upgrades 

• Repairs and exchanges 

• Specialty services 

Our Commitment

Siemens is proud of its reputation for 

long-term service of its products, including

the Perfect Harmony. We are committed 

to providing complete life-cycle support. 

We never relinquish the responsibility 

for servicing our products to the full

satisfaction of our customers, regardless 

of the age of the product. To extend the

lifespan and increase the functionality 

of the drive, the Siemens refurbishment

program provides our customers with 

the opportunity to upgrade their Perfect

Harmony drive with new technology as 

it becomes available.

Local Convenience

Because we are accustomed to providing

on-site service for all of our customers, 

we have the extensive reach of a

dedicated, global service force. Each 

of our service representatives is fully

trained in variable frequency drives. 

We are committed to growing our sales

and service staff and branching out into

new regions to support the growth of 

our installed base.

All Siemens LD-R service representatives are fully trained in medium voltage variable frequency drives, giving Siemens the largest medium

voltage service organization in the world! 

13

Maximum output frequency — 330 Hz (with derating). Speed-control range — 1:1000 (with encoder).

2.3 kV 3.3 kV 4.16 kV

Output Output Output Output Output Output

Current kVA Current kVA Current kVA

70 300 70 400 70 500

100 400 100 600 100 700

140 500 140 800 140 1000

200 800 200 1000 200 1500

260 1000 260 1500 260 1750

315 1250 315 1750 315 2000

375 1500 375 2000 375 2500

500 2000 500 2500 500 3500

660 2500 660 3500 660 4500

880 5000 880 6500

1250 7000 1250 9000

6.0 kV 6.6 kV 11 kV

Output Output Output Output Output Output

Current kVA Current kVA Current kVA

70 700 70 800 500 8000

100 1000 100 1000 800 15000

140 1500 140 1500 1400 25000

200 2000 200 2000

260 2500 260 3000

315 3000 315 3500

375 4000 375 4000

500 5000 500 5500

660 7000 660 7500

880 9000 880 9500

1250 13000 1250 14000

13.8 kV

Output Output

Current kVA

500 10000

800 18000

1400 31000

Output Parameters

Rated Motor Voltage Single Drive Configuration

Technical Specifications

General

Power semiconductors IGBTs; diodes

Line-side converter 18- to 36-pulse diode rectifier (standard)

Motor-side converter Multi-level converter (PWM) 

with IGBT power modules

Closed-loop control Sensorless closed-loop control, 

fully digital with signal processor

Drive quadrants Driving: 2 directions of rotation 

(2 quadrant), 4 quadrant option

Potential separation: 

Power section Fiber-optic cable

- Open- and closed-loop control

Permissible humidity rating Relative air humidity < 95% 

non-condensing

Noise level Approx. 75 dB (A)

Efficiency 96% at the rated operating point 

(standard version) including transformer

Regulations compliances IEEE, ANSI, NEMA, UL, CSA, CE

Paint finish ANSI 61 Gray

Degree of protection Acc. to DIN VDE 0470, IEC 60529, 

EN 60529 

- Standard IP31 (air-cooling) 

IP52 (water-cooling)

NEMA 1 (air-cooling)

NEMA 12 (water-cooling)

- Optional IP42 (air-cooling) 

Cooling Type

Air-cooled Forced-air cooling with integrated fans

Permissible ambient and cooling, medium temperature

- In operation 0ºC to + 40ºC: 100% load capability

+40ºC to 50ºC: current derating 

- During storage -25ºC to +55ºC

- During transport -25ºC to +70ºC

Water-cooled Deionized water with integrated 

water-to-water heat exchanger

Permissible ambient temperature

- In operation +0ºC to + 40ºC

- During storage -25ºC to + 55ºC 

(without deionized water)

- During transport -25ºC to + 70ºC 

(without deionized water)

Permissible cooling medium temperature (raw water)

- Intake +5ºC to 35ºC

- Outlet Max. +40ºC

Supply Data

Standard 2.3 to 15 kV

Special option < 2.3 and > 12 kV

Control voltage 1 Ph, 120 VAC or integrated to 

auxiliary supply

Alarms Meanings

Underload Underload alarm

Single-input phasing Loss of one input phase

Ride through Drive in ride-through operation 

(input voltage dip)

ProToPSTM Alarm and Trip Examples (All Configurable)

Alarms Meanings

Overspeed Alarm speed threshold reached

Overcurrent Alarm current threshold reached

Motor temperature Alarm motor temperature threshold 

reached

Network failure Communication problem

Speed reference signal loss Loss of speed feedback signal

14


Robicon Perfect Harmony Medium Voltage AC Drives
Robicon Perfect Harmony Medium Voltage AC Drives
Long press to look detail
Long by picture save/share

Robicon Perfect Harmony Medium Voltage AC Drives

INQUIRY

Inquiry MORE+
  • Email *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

We are the world's leading supplier of spare parts for medium voltage drives of various brands

GET IN TOUCH

East Sun Industrial Centre, No 16 Shing Yip Street Kl, Hongkong

Call us : +852 5261 7322

SITEMAP

分类标题

BUSINESS HOURS

Monday to Friday : 9 am to 6 pm

Saturday : 9 am to 12 am

Sunday : Closed Support Hours in 24/7 Everyday

DISCLAIMER:

We are not an authorized distributor, reseller or representative of the following products presented on this website. All Product names and logos throughout this site are trademarks of their respective holders. Use of them DOES NOT imply any affiliation with or endorsement by them.

© 2020 robiconperfectharmony.com site . All rights reserved     Site Map

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了