Siemens SIMOREG DC Master 6RA70 Series Base Drive Instruction Manual
Siemens SIMOREG DC Master 6RA70 Series Base Drive Instruction Manual Microprocessor-based converters from 15A -1680A for variable speed DC drives Rev 7.0
Base Drive Panel Catalog Numbers
US RATING
(Amps DC)
1-QUAD TYPE
(Catalog No.)
4-QUAD TYPE
(Catalog No.)
Horsepower
(240V DC 1)
Horsepower
(500V DC)
15 6RA7013-2FS22-0 6RA7013-2FV62-0 3HP 7.5HP
30 6RA7018-2FS22-0 6RA7018-2FV62-0 7.5HP 15HP
60 6RA7025-2FS22-0 6RA7025-2FV62-0 15HP 30HP
100 6RA7030-2FS22-0 6RA7030-2FV62-0 25HP 60HP
140 6RA7072-2FS22-0 6RA7072-2FV62-0 40HP 75HP
210 6RA7075-2FS22-0 6RA7075-2FV62-0 60HP 125HP
255 6RA7077-2FS22-0 6RA7077-2FV62-0 75HP 150HP
430 6RA7082-2FS22-0 6RA7082-2FV62-0 125HP 250HP
510 6RA7083-2FS22-0 6RA7083-2FV62-0 150HP 300HP
850 6RA7087-2FS22-0 6RA7087-2FV62-0 250HP 500HP
1180(2) 6RA7091-2FS22-0 6RA7091-2FV62-0 350HP 700HP
1660(2) 6RA7094-2FS22-0 6RA7094-2FV62-0 500HP 1000HP
1680(2) 6RA7094-2FS22-085 6RA7094-2FV62-085 500HP 1000HP
1) Standard voltage configuration
as shipped is 460V AC.
See Technical application note
for 230V AC connection.
2) Standard voltage configuration
as shipped is 460V AC.
See Technical application note
for 575V AC connection on 1180
1660 & 1680A Base drives
Option Part Numbers
Options Order No.
Terminal expansion card (CUD2) 6RX1700-0AK00
User-friendly operator control panel (OP1S) 6SE7090-0XX84-2FK0
AOP1 adapter for mounting OP1A in cubicle door, including
5 m connecting cable
6SX7010-0AA00
PMU-OP1S connecting cable, 3m 6SX7010-0AB03
PMU-OP1S connecting cable, 5m 6SX7010-0AB05
LBA Local bus adapter for the electronics box
Note: LBA is needed to install any boards listed below
6SE7090-0XX84-4HA0
ADB Adapter board
Note: ADB is always needed to install CBC, CBP2, CBD,
EB1, EB2, SBP and SLB boards
6SE7090-0XX84-0KA0
SBP Pulse encoder evaluation board 1) 2) 6SX7010-0FA00
EB1 Terminal expansion board 2) 6SX7010-0KB00
EB2 Terminal expansion board 2) 6SX7010-0KC00
SLB SIMOLINK board 2) 6SX7010-0FJ00
CBP2 Communications board interface for PROFIBUS 2) 6SX7010-0FF05
CBC Communications board interface for CAN protocol 2) 6SX7010-0FG00
CBD Communications board interface for DeviceNet protocol 2) 6SX7010-0FK00
T400 Technology board with SPW 420 Axial winder software 2) 6DD1-842-0AA0
T400 Technology board with SPW 440 Angular Synchr. Software 2) 6DD1-842-0ABO
1) A pulse encoder evaluation circuit is a standard component of the basic SIMOREG converter. The SBP only
needs to be ordered in configurations requiring evaluation of a second pulse encoder.
2) The LBA local bus adapter and ADB adapter board must be ordered as additional components for installing
supplementary boards in the SIMOREG converter.
Printed Circuit Boards
DESCRIPTION WHERE USED
US Rating 460V
PART
NUMBER
RECOM
SPARE
Microprocessor board CUD1
(C98 043-A7001-L1)
All Ratings 6RY1703-0AA00 1
Power Interface board 1Q (85 to 575 VAC)
(C98 043-A7002-L1)
All 1Q Ratings 6RY1703-0DA01 1
Power Interface board 4Q (85 to 575 VAC)
(C98 043-A7002-L4)
All 4Q Ratings 6RY1703-0DA02 1
PMU Operator Panel (C98 043-A7005-L1) All Ratings 6RY1704-0AA00 -
Field Supply board (C98 043-A7014-L1) 30 to 100 Amp 6RY1703-0CA03 1
Field Supply board (C98 043-A7014-L2) 140 to 510 Amp 6RY1703-0CA01 1
Field Supply board (C98 043-A7004-L1) 850 to 1660 Amp 6RY1703-0EA01 1
Field Supply board (C98 043-A7004-L3) 1680 Amp 6RY1703-0EA03 1
Snubber board (C98 043-A7007-L4) 60 to 100 Amp 6RY1703-0FA04
Snubber board (C98 043-A7007-L6) 30, 140 & 210 Amp 6RY1703-0FA11 -
Snubber board (C98 043-A7011-L6) 255 & 430 Amp 6RY1703-0FA10 -
Snubber boards (C98 043-A7011-L1) 510 & 850 Amp 6RY1703-0FA06 -
Main Power Section Connector board
(C98 043-A7010-L2)
15 Amp (1Q, 4Q) 6RY1703-0CA04 1
Fuse for Power Supply, 1 amp F1, F2
Mounted on Power Interface board
15 – 1680 Amp 6RY1702-0BA00 2
Cables
DESCRIPTION WHERE USED
US Rating 460V
PART
NUMBER
RECOM
SPARE
Ribbon Cable 20 pole X102 15 amp 6RY1707-0AA00
Ribbon Cable 64 pole X101 15 to 430 amp 6RY1707-0AA01 -
Ribbon Cable 20 pole X102 30 to 210 amp 6RY1707-0AA02 -
Ribbon Cable 20 pole X102 255 & 430 amp 6RY1707-0AA03 -
Ribbon Cable 20 pole X102 510 amp 6RY1707-0AA12 -
Ribbon Cable 64 pole X101 510 amp 6RY1707-0AA05 -
Ribbon Cable 20 pole X102 850 to 1680 amp 6RY1707-0AA06 -
Ribbon Cable 64 pole X101 850 to 1680 amp 6RY1707-0AA07 -
L2)
01
Siemens Energy & Automation 3-5
SIMOREG DC Master Base Drive Panel Operating Instructions
Fans/Blowers
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
FAN, 24 VDC
(C98130-A1256-C553)
140 & 210 amp 6RY1701-0AA07 2
FAN, 230 VAC, 1 Phase
(C98130-A7004-B130)
255, 430 & 510
amp
6RY1701-0AA11 1
FAN, 230 VAC, 1 Phase
(C98130-A7004-B330)
850 amp 6RY1701-0AA12 1
FAN, 460 VAC, 3 Phase
(C98 247-S1002-C25)
1180, 1660
&1680 amp
6RY1701-0AA04 1
Thyristors & Diodes
Armature Converter Thyristor Modules, (for 1-Quad Drives)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
Dual Thyristor Module 15 amp 1Q 6RY1700-0AA16 3
Dual Thyristor Module 30 amp 1Q 6RY1700-0AA17 3
Dual Thyristor Module 60 amp 1Q 6RY1700-0AA18 3
Dual Thyristor Module 100 amp 1Q 6RY1700-0AA11 3
Dual Thyristor Module 140 amp 1Q 6RY1700-0AA14 3
Dual Thyristor Module 210 amp 1Q 6SY7010-0AA02 3
Dual Thyristor Module 255 amp 1Q 6RY1700-0AA15 3
Dual Thyristor Module 430 amp 1Q 6SY7010-0AA05 3
Dual Thyristor Module 510 amp 1Q 6SY7010-0AA04 3
Dual Thyristor Module 850 amp 1Q 6RY1700-0AA04 3
Thyristor/Heatsink Assembly, Front
(C98 130-A1255-B510)
1180 amp 1Q 6RY1702-0CA15 2
Thyristor/Heatsink Assembly, Back
(C98 130-A1255-B511)
1180 amp 1Q 6RY1702-0CA16 2
Thyristor/Heatsink Assembly, Front
(C98 130-A1255-B520)
1660 amp 1Q 6RY1702-0CA17 2
Thyristor/Heatsink Assembly, Back
(C98 130-A1255-B521)
1660 amp 1Q 6RY1702-0CA18 2
Thyristor/Heatsink Assembly, Front 1680 amp 1Q 6RY1702-0CA30 2
Thyristor/Heatsink Assembly, Back 1680 amp 1Q 6RY1702-0CA31 2
3-6 Siemens Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
Armature Converter Thyristor Modules, (for 4-Quad Drives)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
Dual Thyristor Module 15 amp 4Q 6RY1700-0AA16 3
Dual Thyristor Module 30 amp 4Q 6RY1700-0AA17 3
Dual Thyristor Module 60 & 100 amp 4Q 6RY1700-0AA11 3
Dual Thyristor Module 140 amp 4Q 6RY1700-0AA14 3
Dual Thyristor Module 210 amp 4Q 6SY7010-0AA02 3
Dual Thyristor Module 255 amp 4Q 6RY1700-0AA15 3
Dual Thyristor Module 430 amp 4Q 6SY7010-0AA05 3
Dual Thyristor Module 510 to 850 amp 4Q 6SY7010-0AA04 3
Thyristor/Heatsink Assembly
C98 130-A1256-B510
1180 amp 4Q 6RY1702-0CA02 2
Thyristor/Heatsink Assembly
C98 130-A1256-B520
1660 amp 4Q 6RY1702-0CA03 2
Thyristor/Heatsink Assembly 1680 amp 4Q 6RY1702-0CA34 2
Field Converter Thyristor Modules
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
Dual Thyristor Module 15 to 430 amp 6RY1700-0AA12 1
Dual Thyristor Module 510 to 1660 amp 6RY1700-0AA17 1
Dual Thyristor Module 1680 amp 6RY1700-0AA05 1
Field Converter Diode Modules
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
Dual Diode Module 15 to 430 amp 6RY1700-0BA04 1
Dual Diode Module 510 to 1660 amp 6RY1700-0BA01 1
Dual Diode Module 1680 AMP 6RY1700-0BA05 1
Siemens Energy & Automation 3-7
SIMOREG DC Master Base Drive Panel Operating Instructions
Power Fuses
Armature Converter AC Line Fuses, (1PFU - 3 PFU)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
25 amp, 700 volt 15 amp A1-FUF-END-C25 3
50 amp, 700 volt 30 amp A1-FUF-END-CDN 3
70 amp, 500 volt 60 amp A1-FUF-00D-014 3
125 amp, 500 volt 100 amp A1-FUF-00D-018 3
150 amp, 500 volt 140 amp A1-FUF-00D-019 3
200 amp, 500 volt 210 amp A1-FUF-00D-021 3
250 amp, 500 volt 255 amp A1-FUF-00D-023 3
400 amp, 500 volt 430 amp A1-FUF-00D-028 3
500 amp, 500 volt 510 amp A1-FUF-00D-030 3
800 amp, 800 volt (Leg Fuse) 850 amp 3NE3338-8 3
1000 amp, 660 volt (Leg Fuse) 1180 amp 6RY1702-0BA02 3
1250 amp, 660 volt (Leg Fuse) 1660 amp 6RY1702-0BA01 3
1500 amp, 660 volt (Leg Fuse) 1680 amp 6RY1702-0BA05 3
Armature Converter DC Fuses, 4-Quad Only, (4PFU)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
25 amp, 700 volt 15 amp A1-FUF-END-C25 2
50 amp, 700 volt 30 amp A1-FUF-END-CDN 2
90 amp, 700 volt 60 amp A1-FUF-00E-016 2
150 amp, 700 volt 100 amp A1-FUF-00E-019 2
175 amp, 700 volt 140 amp A1-FUF-00E-020 2
250 amp, 700 volt 210 amp A1-FUF-00E-023 2
300 amp, 700 volt 255 amp A1-FUF-00E-025 2
500 amp, 700 volt 430 amp A1-FUF-00E-030 2
600 amp, 700 volt 510 amp A1-FUF-00E-031 2
3-8 Siemens Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
Field Converter AC Line Fuses (1 & 2FSFU)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
20 amp, 700 volt 60 to 210 amp A1-FUF-END-C20 2
40 amp, 700 volt 255 to 850 amp A1-FUF-END-C40 2
50 amp, 700 volt 1180 to 1660 amp A1-FUF-END-C50 2
125 amp, 600 volt 1680 amp A1-FUF-HHA-024 2
Control Transformer Primary Fuses (1CFU, 2CFU)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
1.25 amp, 600 volt, Class "CC" 15 to 100 amp A1-FUF-AFA-006 2
2.5 amp, 600 volt, Class "CC" 140 & 210 amp
1180, 1660 &
1680 amp
A1-FUF-AFA-011 2
3.5 amp, 600 volt, Class "CC" 255 to 510 amp
850 amp, (460
volt input only)
A1-FUF-AFA-014 2
5 amp, 600 volt, Class "CC" 1180, 1660 &
1680 amp
(4CFU, 5CFU,
6CFU, 7CFU)
A1-FUF-AFA-016 4
Control Transformer Secondary Fuse (3CFU)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
0.75 amp, 250 volt, Type MDL 15 to 100 amp A1-FUF-DKA-GBF 2
1.5 amp, 250 volt, Type MDL 140 & 210 amp
1180,1660 &
1680 amp
A1-FUF-DKA-GBP 2
2 amp, 250 volt, Type MDL 255 to 510 amp A1-FUF-DKA-GBV 2
6.25 amp, 250 volt, Type MDL 850 amp A1-FUF-DKA-GCM 2
Siemens Energy & Automation 3-9
SIMOREG DC Master Base Drive Panel Operating Instructions
Control Transformer (1CTR, 2CTR, 3CTR)
DESCRIPTION
460 VAC Primary
WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
115 VA, 230 VAC secondary 15 to 100 amp A1-TRC-Q0C-285 -
250 VA, 230 VAC secondary 140 & 210 amp
1180, 1660 &
1680 amp
A1-TRC-Q0C-286 -
350 VA, 230 VAC secondary 255 to 510 amp A1-TRC-Q0C-287 -
1000 VA, 230 VAC secondary 850 amp A1-TRC-Q0C-288 -
750 VA, 460 VAC secondary 1180,1660 &
1680 amp
A1-TRC-Q0C-289 -
Main Contactor (M)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
3 Pole AC contactor, 240 VAC coil 15 amp 3RT1016-1AP61 -
3 Pole AC contactor, 240 VAC coil 30 amp 3RT1025-1AP60 -
3 Pole AC contactor, 240 VAC coil 60 amp 3RT1035-1AP60 -
3 Pole AC contactor, 240 VAC coil 100 amp 3RT1044-1AP60 -
3 Pole AC contactor, 240 VAC coil 140 amp 3RT1045-1AP60 -
3 Pole AC contactor, 240 VAC coil 210 amp 3RT1456-6AP36 -
3 Pole AC contactor, 240 VAC coil 255 amp 3RT1456-6AP36 -
1 Pole DC contactor, 250 VDC coil 430 to 1680 amp A1-CRD-CAC-010 -
Contactor Coil Suppressor (1SP, ENSP)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
Suppressor, varistor type 127 – 240 V 15 amp
430 to 1680 amp
3RT1916-1BD00 -
Suppressor, varistor type 127 – 240 V 30 to 140 amp 3RT1926-1BD00 -
Auxiliary Relay, (EN), and Rectifier Bridge, (MREC)
DESCRIPTION WHERE USED
US Rating 460V
PART NUMBER RECOM
SPARE
Relay, 2-NO, 2-NC, 230 VAC coil 430 to 1680 amp 3RH1122-1AP60 -
Rectifier Bridge, 1 Phase, 5A, 800 V 430 to 1680 amp A1-116-002-001

Copy product links
Long by picture save/share